產(chǎn)品中心

            大鼠抗繆勒管激素(AMH)酶聯(lián)免疫吸附檢測試劑盒
            ELK0211
            規(guī)格: 價格:
            48T ¥1960.00
            96T ¥2800.00

            Overview 文獻

            Product name: Rat AMH(Anti-Mullerian Hormone) ELISA Kit
            Reactivity: Rat
            Alternative Names: MIF; MIH; MIS; Müllerian Inhibiting Factor; Müllerian Inhibiting Hormone; Müllerian Inhibiting Substance
            Assay Type: Sandwich
            Sensitivity: 1.11 ng/mL
            Standard: 150 ng/mL
            Detection Range: 2.35-150 ng/mL
            Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
            Assay Length: 3.5h
            Research Area: Endocrinology;Reproductive science;Hormone metabolism;
            Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat AMH. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat AMH. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat AMH, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat AMH in the samples is then determined by comparing the OD of the samples to the standard curve.

            標準曲線

            Concentration (ng/mL) OD Corrected OD
            150.00 2.168 2.060
            75.00 1.648 1.540
            37.50 1.277 1.169
            18.75 0.847 0.739
            9.38 0.505 0.397
            4.69 0.381 0.273
            2.35 0.256 0.148
            0.00 0.108 0.000

            精密度

            Intra-assay Precision (Precision within an assay):CV%<8%

            Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

            Inter-assay Precision (Precision between assays):CV%<10%

            Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

            回收率

            Matrices listed below were spiked with certain level of recombinant AMH and the recovery rates were calculated by comparing the measured value to the expected amount of AMH in samples.
            Matrix Recovery range Average
            serum(n=5) 85-97% 91%
            EDTA plasma(n=5) 91-105% 98%
            Heparin plasma(n=5) 81-95% 88%

            線性

            The linearity of the kit was assayed by testing samples spiked with appropriate concentration of AMH and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
            Matrix 1:2 1:4 1:8 1:16
            serum(n=5) 88-100% 95-103% 89-97% 85-94%
            EDTA plasma(n=5) 88-97% 86-97% 85-103% 89-97%
            Heparin plasma(n=5) 81-94% 83-96% 87-98% 85-97%
            關(guān)閉