            Product name: Rat IAPP(Islet Amyloid Polypeptide) ELISA Kit
            Reactivity: Rat
            Alternative Names: IAP; DAP; Amylin; Insulinoma Amyloid Polypeptide; Diabetes-associated peptide
            Assay Type: Competitive Inhibition
            Sensitivity: 2.83 pg/mL
            Standard: 500 pg/mL
            Detection Range: 7.82-500 pg/mL
            Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
            Assay Length: 2h
            Research Area: Metabolic pathway;Endocrinology;Hepatology;
            Uniprot ID: P12969
            Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Rat IAPP protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat IAPP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat IAPP in the samples is then determined by comparing the OD of the samples to the standard curve.

            標(biāo)準(zhǔn)曲線

            Concentration (pg/mL) OD Corrected OD
            500.00 0.221
            250.00 0.387
            125.00 0.689
            62.50 0.913
            31.25 1.225
            15.63 1.596
            7.82 1.871
            0.00 2.316

            精密度

            Intra-assay Precision (Precision within an assay):CV%<8%

            Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

            Inter-assay Precision (Precision between assays):CV%<10%

            Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

            回收率

            Matrices listed below were spiked with certain level of recombinant IAPP and the recovery rates were calculated by comparing the measured value to the expected amount of IAPP in samples.
            Matrix Recovery range Average
            serum(n=5) 85-97% 91%
            EDTA plasma(n=5) 82-94% 88%
            Heparin plasma(n=5) 89-107% 98%

            線性

            The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IAPP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
            Matrix 1:2 1:4 1:8 1:16
            serum(n=5) 95-104% 97-105% 82-95% 89-97%
            EDTA plasma(n=5) 86-95% 82-93% 97-106% 89-102%
            Heparin plasma(n=5) 95-104% 82-96% 92-103% 90-99%